Journal of the American Dental Association, Vol 122, Issue 10, 51-56
Copyright © 1991 by American Dental Association
Effectiveness of dental office instrument sterilization procedures
RJ Hastreiter,
JA Molinari,
MC Falken,
MH Roesch,
MJ Gleason,
and
VA Merchant
Dental Health Section, Minnesota Department of Health, Minneapolis 55440.
To evaluate instrument sterilization procedures in Minnesota, biological indicators were used to monitor 406 sterilizers in 381 dental offices. Findings suggest a general improvement in instrument performance over that of a decade ago, but sterilization failure rates are still too high. Sterilizer operator errors are a major cause of sterilization failures. BIs are useful in monitoring sterilization performance only when sterilization procedures are performed consistently and competently by well-trained staff using adequately maintained equipment.