The Journal of the American Dental Association
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Am Dent Assoc, Vol 134, No 3, 325-330.
© 2003 American Dental Association

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by WILLIAMS, H. N.
Right arrow Articles by ROMBERG, E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by WILLIAMS, H. N.
Right arrow Articles by ROMBERG, E.
Related Collections
Right arrow Infection Control

CLINICAL PRACTICE

JADA Continuing Education

Surface contamination in the dental operatory

A comparison over two decades



HENRY N. WILLIAMS, Ph.D., RUBY SINGH, Ph.D. and ELAINE ROMBERG, Ph.D.

Background. This study compares surface bacterial contamination levels in a large teaching clinic in 1998 with that of a 1976 study in the same clinic to determine if renovation and more stringent infection control, or IC, practices have made a difference.

Methods. The authors obtained samples from surfaces in clinic operatories—including the light handle covers, jacket cuffs, sinks and floors—in the morning and afternoon. They compared the bacterial counts from these samples with those from the 1976 study. Data were analyzed using the matched pairs t tests and independent t tests.

Results. In both the 1976 and 1998 studies, mean bacterial counts were higher at the end of the day than in the morning; however, the differences were only significant in the 1976 study. Comparisons between the 1998 and 1976 counts revealed significant differences for the floor, head-rest, light handle covers and clinic jacket cuffs.

Conclusions. Improvements in clinic design and equipment, as well as IC procedures and practices resulted in a lower level of surface bacterial contamination in 1998 than in 1976 in a large teaching clinic.

Clinical Implications. Attention to clinic design and furnishings and adherence to recommended IC practices can reduce microbial surface contamination, thereby reducing the risk of causing cross-infection and making dental practice safer.