The Journal of the American Dental Association
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Am Dent Assoc, Vol 135, No 4, 429-437.
© 2004 American Dental Association

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by HARREL, S. K.
Right arrow Articles by MOLINARI, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by HARREL, S. K.
Right arrow Articles by MOLINARI, J.
Related Collections
Right arrow Infection Control

CLINICAL PRACTICE

COVER STORY
JADA Continuing Education

Aerosols and splatter in dentistry

A brief review of the literature and infection control implications



STEPHEN K. HARREL, D.D.S. and JOHN MOLINARI, Ph.D.

Background. Aerosols and droplets are produced during many dental procedures. With the advent of the droplet-spread disease severe acute respiratory syndrome, or SARS, a review of the infection control procedures for aerosols is warranted.

Types of Studies Reviewed. The authors reviewed representative medical and dental literature for studies and reports that documented the spread of disease through an airborne route. They also reviewed the dental literature for representative studies of contamination from various dental procedures and methods of reducing airborne contamination from those procedures.

Results. The airborne spread of measles, tuberculosis and SARS is well-documented in the medical literature. The dental literature shows that many dental procedures produce aerosols and droplets that are contaminated with bacteria and blood. These aerosols represent a potential route for disease transmission. The literature also documents that airborne contamination can be minimized easily and inexpensively by layering several infection control steps into the routine precautions used during all dental procedures.

Clinical Implications. In addition to the routine use of standard barriers such as masks and gloves, the universal use of pre-procedural rinses and high-volume evacuation is recommended.