The Journal of the American Dental Association
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Am Dent Assoc, Vol 136, No 7, 877-882.
© 2005 American Dental Association

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by CHECCHI, L.
Right arrow Articles by VIOLANTE, F. S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by CHECCHI, L.
Right arrow Articles by VIOLANTE, F. S.
Related Collections
Right arrow Dental Equipment/Instruments

COVER STORY

JADA Continuing Education

Efficacy of three face masks in preventing inhalation of airborne contaminants in dental practice



LUIGI CHECCHI, M.D., M.S., MARCO MONTEVECCHI, D.D.S., ANNALISA MORESCHI, D.D.S., FRANCESCA GRAZIOSI, M.D., PAOLA TADDEI, Ph.D. and FRANCESCO SAVERIO VIOLANTE, M.D.

Background. Up-to-date studies are needed on the protection provided by face masks used by dentists. We assessed the relative filtering efficacy of two currently used surgical face masks (one a molded mask, the other a tie-on mask) and a certified personal particulate respirator, all made by a single manufacturer.

Methods. The authors sprayed bicarbonate particulate against a porcelain surface (representing the patient’s mouth) and collected it via a mannequin head (representing the dentist’s head) placed 40 centimeters away and a tube with two airflow rates (0.5 cubic meters per hour and 9 m3/hour). They calculated the dry residue weight. They performed three separate runs for each mask and three runs with no mask at the two airflow rates with and without aerosol.

Results. With no mask (control), the authors recorded significant weight gains at both airflow rates with and without vaporization. With vaporization, the three masks were associated with different dry residue weights (P < .03 with the Kruskal-Wallis test at both flow rates), the respirator providing the lowest amount. The respirator provided an efficiency of 94 to 96 percent, compared with 90 to 92 percent and 85 to 86 percent for the molded and tie-on surgical masks, respectively.

Conclusions. These data provide independent evidence that a certified personal respirator can be more effective than high-quality surgical masks in dental settings.

Clinical Implications. Dentists should be aware that a certified particulate respirator can provide them with superior filtering protection.

Key Words: Surgical masks; infection control; particulate; respirators