The Journal of the American Dental Association
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Am Dent Assoc, Vol 137, No suppl_1, 22S-31S.
© 2006 American Dental Association

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Continuing Education
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Fasbinder, D. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Fasbinder, D. J.

ARTICLES

JADA Continuing Education

Clinical performance of chairside CAD/CAM restorations



Dennis J. Fasbinder, DDS

Background. The CEREC system (Sirona Dental Systems GmbH, Bensheim, Germany) is marking its 20th year of clinical service. The author reviews the literature on the effectiveness of this chairside CAD/CAM system.

Types of Studies Reviewed. The author identified and reviewed clinical studies from 1985 through 2006 that included CEREC-generated inlays, onlays or crowns. These studies were conducted in both private practice and university settings. The author summarized the findings as they relate to postoperative sensitivity, restoration fracture, color match, margin adaptation and clinical longevity.

Results. Although postoperative sensitivity was reported, it was due to mainly occlusal interferences. Long-term postoperative sensitivity was not a reported problem. Similar to other ceramic restorations, restoration fracture is the primary mode of failure for CEREC-generated restorations. Although margin wear is detected consistently, consequences of the wear leading to restoration failure were reported rarely. The survival probability of CEREC-generated restorations was reported to be approximately 97 percent for five years and 90 percent for 10 years.

Clinical Implications. The low rate of restoration fracture and long-term clinical survivability document the effectiveness of the CEREC system as a dependable, esthetic restorative option for patients.

Key Words: Computer-aided design/computer-aided manufacturing; ceramics; clinical studies; margin wear







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright©1995-2006 American Dental Association (ADA).
Reproduction or republication strictly prohibited without prior written permission of ADA.