The Journal of the American Dental Association
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Am Dent Assoc, Vol 139, No 12, 1632-1642.
© 2008 American Dental Association

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Thyvalikakath, T. P.
Right arrow Articles by Schleyer, T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Thyvalikakath, T. P.
Right arrow Articles by Schleyer, T.
Related Collections
Right arrow Dental Equipment/Instruments

RESEARCH

A usability evaluation of four commercial dental computer-based patient record systems



Thankam P. Thyvalikakath, BDS, MS, Valerie Monaco, PhD, MHCI, Hima Bindu Thambuganipalle, BDS and Titus Schleyer, DMD, PhD

Background. The usability of dental computer-based patient record (CPR) systems has not been studied, despite early evidence that poor usability is a problem for dental CPR system users at multiple levels.

Methods. The authors conducted formal usability tests of four dental CPR systems by using a purposive sample of four groups of five novice users. The authors measured task outcomes (correctly completed, incorrectly completed and incomplete) in each CPR system while the participants performed nine clinical documentation tasks, as well as the number of usability problems identified in each CPR system and their potential relationship to task outcomes. The authors reviewed the software application design aspects responsible for these usability problems.

Results. The range for correctly completed tasks was 16 to 64 percent, for incorrectly completed tasks 18 to 38 percent and for incomplete tasks 9 to 47 percent. The authors identified 286 usability problems. The main types were three unsuccessful attempts, negative affect and task incorrectly completed. They also identified six problematic interface and interaction designs that led to usability problems.

Conclusion. The four dental CPR systems studied have significant usability problems for novice users, resulting in a steep learning curve and potentially reduced system adoption.

Clinical Implications. The significant number of data entry errors raises concerns about the quality of documentation in clinical practice.

Key Words: Usability; computer-based patient records; clinical information systems; evaluation; user interface

Abbreviations: CPRs: Computer-based patient records. • DX: Dentrix. • ES: EagleSoft. • NCRR: National Center for Research Resources. • NIH: National Institutes of Health. • PW: PracticeWorks. • SD: SoftDent. • SDM: School of Dental Medicine.