The Journal of the American Dental Association
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Am Dent Assoc, Vol 140, No 3, 331-338.
© 2009 American Dental Association

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Yue, C.
Right arrow Articles by Feigal, R. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Yue, C.
Right arrow Articles by Feigal, R. J.

RESEARCH

JADA Continuing Education

The Depth of Cure of Clear Versus Opaque Sealants as Influenced by Curing Regimens



Christopher Yue, DMD, MS, Daranee Tantbirojn, DDS, MS, PhD, Ronald L. Grothe, DDS, MS, MBA, Antheunis Versluis, PhD, James S. Hodges, PhD and Robert J. Feigal, DDS, PhD

Background. The authors conducted a study to test the hypothesis that light-curing regimens affect depth of cure of clear versus opaque sealants.

Methods. The authors light-cured samples of one clear and two opaque sealants at 20 seconds, 0 millimeters; 40 seconds, 0 mm; and 40 seconds, 2.2 mm (n = 5 each). They assessed the depth of cure with Knoop hardness at 0.5-mm increments five minutes and one hour after curing. The authors used analysis of variance.

Results. Curing regimens and sealant types affected the depth of cure. The clear sealant maintained a greater hardness than did the opaque sealants through a depth of 3 mm (P < .001). A 20-second duration reduced the depth of cure for all sealants (P < .001). The distance from the light source did not affect the cure depth of the clear sealant (P = .34), but it reduced the cure depth of the opaque sealants (P < .05). Sealant hardness increased significantly one hour after light curing (P < .001).

Conclusions. A clear sealant cured deeper than did opaque sealants. Curing duration is crucial to achieve an adequate depth of cure. A 20-second duration may not suffice. Light source distance affected the depth of cure for the opaque sealants, but not for the clear sealant with sufficient curing duration.

Clinical Implications. The authors advocate a curing duration of longer than 20 seconds to ensure thorough polymerization at the interface between the sealant and tooth. Insufficient curing could contribute to failure of the sealants, especially the opaque sealants, under clinical conditions that restrict the light tip position.

Key Words: Sealant; depth of cure; curing duration; distance; hardness; postirradiation

Abbreviations: ANSI/ADA: American National Standards Institute/American Dental Association. • Bis-GMA: Bisphenol A glycidyl dimethacrylate. • ISO: International Organization for Standardization. • KHN: Knoop hardness number. • NA: Not applicable. • TEGDMA: Triethylene glycol dimethacrylate.